Pie Medical Imaging (PMI) / Key word(s): Miscellaneous
FAST III trial demonstrates non-inferiority of CAAS vFFR to invasive wire-based FFR

29.03.2026 / 17:05 CET/CEST
The issuer is solely responsible for the content of this announcement.

  • FAST III was initiated five years ago to evaluate whether revascularization guided by angiography–based FFR using CAAS vFFR (vessel Fractional Flow Reserve) delivers therapeutic outcomes comparable to those achieved with pressure wire–based FFR.
  • Positive non-inferior result validates angiography–based vFFR as a safe and effective alternative for guiding revascularization
  • Paves the way for reimbursement of less invasive testing for patients with intermediate coronary stenoses
  • FAST III is a study sponsored by the European Cardiovascular Research Institute, supported by research grants from industry partners Siemens Healthineers and Pie Medical Imaging.

MAASTRICHT, Netherlands, March 29, 2026 /PRNewswire/ -- Pie Medical Imaging, a global leader in cardiac imaging analysis Solutions announces the result of the FAST III trial, presented during the Late-Breaking Clinical Trials session at the Congress of the American College of Cardiology (ACC) 2026 and published in the New England Journal of Medicine. The trial confirms non-inferiority of revascularization guided by CAAS vFFR to revascularization guided by pressure wire-based FFR.

Interface of CAAS vFFR for real-time in‑cathlab assessment of lesion significance.

FAST III was an investigator-initiated, open label, multicenter randomized trial comparing vFFR guided versus FFR guided coronary revascularization in 2235 patients with intermediate coronary lesions (defined as 30%-80% stenosis by visual assessment or QCA). Intermediate lesions were physiologically assessed using table side vFFR or FFR and treated if vFFR or FFR ≤0.80. The primary end point was a composite of all-cause death, any myocardial infarction, or any revascularization at 1-year post-randomization.

Following the tremendous efforts of the principal investigator, Dr. Joost Daemen, cardiologist in the Thoraxcenter at the Erasmus University Medical Center in Rotterdam, Netherlands. 37 participating centers and ECRI (sponsor of the trial), the trial has met its primary endpoint, showing identical MACE rates in the vFFR-guided group and the FFR-guided group.

"The results of FAST III confirm the safety and feasibility of the online use of vFFR as an easy to use minimally invasive tool to guide revascularization in patients with intermediate coronary artery lesions in need of physiological lesion assessment. The technology has the potential to boost the use of physiology, which may increase the prognosis of patients in whom the decision to revascularize intermediate coronary artery lesions is still largely based on eye-balling. The use of vFFR eliminates the need for guiding catheters, invasive coronary artery instrumentation and hyperemic agents with inherent risks and patient discomfort," said Dr. Joost Daemen.

Bas Kuppens, CEO at Pie Medical Imaging adds: "FAST III marks a defining moment. It confirms angiography-based physiology is non-inferior to conventional pressure wire-based physiology. Additionally, it has demonstrated benefits for care givers and patients by requiring less dose, less contrast agent, and reducing procedure lead time".

Doris Pommi, head of Cardiovascular Care at Siemens Healthineers, added: "The results of the FAST III study mark a significant milestone for cardiovascular care in Europe and for our partnership with Pie Medical Imaging. Its success shows how much we can achieve when we join forces and combine scientific excellence, clinical experience, and industrial innovation. (The patient impact of the study is substantial, we are looking at safer, faster, less uncomfortable coronary assessments with potentially lower costs and wider access to physiologic lesion evaluation.)"

The trial is funded by research grants from Pie Medical Imaging (Maastricht, The Netherlands) and Siemens Healthineers AG (Forchheim, Germany). The study is sponsored by ECRI (European Cardiovascular Research Institute, Rotterdam-the Netherlands). Cardialysis (Rotterdam, The Netherlands) is responsible for trial services including trial management and Core Laboratory activities.

About Pie Medical Imaging

Pie Medical Imaging is a global leader in advanced cardiovascular image analysis, quantification and visualization. Based in Maastricht, The Netherlands, the company oversees worldwide innovation and commercialization of the CAAS and 3mensio product lines. With decades of expertise and deep commitment to innovation, Pie Medical Imaging delivers software solutions that empower clinicians, researchers, and industry partners to enhance diagnosis, procedure planning, and image-guided interventions.

The company complies with international quality and regulatory standards, ensuring high reliability and clinical confidence.

Pie Medical Imaging is part of the Esaote Group, a leader in the biomedical equipment sector.

More information about Pie Medical Imaging is available at www.piemedicalimaging.com.

Pie Medical Imaging Logo

Photo - https://mma.prnewswire.com/media/2943619/FAST_III_PR_Image.jpg
Logo - https://mma.prnewswire.com/media/2438117/PMI_logo.jpg

Cision
View original content:https://www.prnewswire.co.uk/news-releases/fast-iii-trial-demonstrates-non-inferiority-of-caas-vffr-to-invasive-wire-based-ffr-302727552.html

rt.gif?NewsItemId=EN20550&Transmission_Id=202603291100PR_NEWS_EURO_ND__EN20550&DateId=20260329

29.03.2026 CET/CEST Dissemination of a Corporate News, transmitted by EQS News - a service of EQS Group.
The issuer is solely responsible for the content of this announcement.

The EQS Distribution Services include Regulatory Announcements, Financial/Corporate News and Press Releases.

2299744  29.03.2026 CET/CEST

Läs mer på EQS Newswire

Marknadsöversikt

1 DAG %

Senast

1 mån